plate heat exchanger | Stock number: 1400425

Unfortunately, the machine has already been sold.
Hot water generator Cat. IV ( 2 pieces available see type/ price per piece!!)
Exhaust gas heat exchanger
Last pressure test (holding time approx. 30 minutes) TÜV Süd on 19.06.2007 and 05.05.2005
Exchange area 61 m²
Heat output 540 kW
Flue gas medium: (through pipes)
-Exhaust gas volume 2381 kg/h
-Operating temperature max. 800°C
-operating overpressure max. 0.1 bar
-Temperature inlet/outlet: 505°/123°C
Cooling medium: (around pipes)
-Water medium
-Operating temperature max. 120°C
-Operating pressure max. 16 bar
-Capacity 274 liters
-Volume nominal operation 12 m³Minum 14.4 m³/h
-Temperature min. 10°C; inlet 92.5°C, outlet 110°C
Flue gas inlet:
-2 inlets, pipe connection Ø 320 x 140mm
-Flange connection pipe size Ø 250mm; flange Ø 345 x 8mm
Exhaust gas outlet:
-2 outlets; pipe connection Ø 320mm; pipe size Ø 500mm, flange Ø 600 x 12mm
Water connection:
Water outlet 1 inch
Subject to changes and errors in technical details and specifications, as well as prior sale.